- Inicio>
- KRIWAN>
- Protectores de motor>
- INT69 SE-B2 22A608
INT69 SE-B2 22A608
Modulo protector INT69 SE-B2 (INT69B2)
0
Productdetails
Supply voltage | AC 115-230V |
Permitted ambient temperature | -30...+70°C |
Temperature measuring circuits: Type | 1-9 PTC sensors acc. to DIN 44081, DIN 44082 in series |
Temperature measuring circuits: R_25, total | <1.8kΩ |
Temperature measuring circuits: R_trip | 4.5kΩ ±20% |
Temperature measuring circuits: R_trip, static | 4.5kΩ ±20% |
Temperature measuring circuits: R_reset | 2.75kΩ ±20% |
Temperature measuring circuits: Max. length connection line | 30m |
Resetting the lock | Main reset >5s only possible if there is no error current |
Relay: Connection | AC 240V 2.5A C300 at least AC/DC 24V 20mA |
Relay: Mechanical service life | Approx. 1 million switching cycles |
Protection class acc. To EN 60529 | IP00 |
Connection type | Flat plug sleeves (PTC), screw terminals |
Housing material | PA glass-fibre-reinforced |
Mounting | Can be snapped onto 35mm standard rail acc. to EN 60715 or screw mounted |
Dimensions | Refer to dimensions in mm |
Weight | Approx. 200g |
Check base | EN 61000-6-2, EN 61000-6-3 EN 61010-1 Overvoltage category II Pollution level 2 |
Approval | UL File No. E75899 cURus |
Información adicional